Sedgewood Commons was recognized and ceritified in 1994 by Centers for Medicare & Medicaid Services as one of model nursing home providers promoting health and improving quality of life. Sedgewood Commons which is located in 22 Northbrook Dr Falmouth, is scientifically measured and assessed by Centers for Medicare & Medicaid Services and is shown to provide good nursing home services or products under the Medicare program. Sedgewood Commons is being offered ceritified services and products in Maine.
County: Cumberland Federal Provider Number: 205159
Participates in: Medicare And Medicaid Certified Date: Wednesday, January 19, 1994 (31 years certified) Certified Agency: Centers for Medicare & Medicaid Services Legal Business Name: Falmouth Operations Llc Ownership Type: For Profit - Corporation Provider Changed Ownership in Last 12 Months: No
Type
Name
Role Description
Organization
Fc-Gen Operations Investment Llc
5% Or More Ownership Interest
Organization
Donna Reis 1995 Fam Tr
5% Or More Ownership Interest
Organization
Gazelle Gen Llc
5% Or More Ownership Interest
Organization
Gen Management Llc
5% Or More Ownership Interest
Organization
Gen Operations I Llc
5% Or More Ownership Interest
Organization
Gen Operations Ii, Llc
5% Or More Ownership Interest
Organization
Genesis Healthcare Llc
5% Or More Ownership Interest
Organization
Genesis Healthcare Llc
Operational/managerial Control
Organization
Genesis Healthcare Of Maine Llc
5% Or More Ownership Interest
Organization
Genesis Operations Llc
5% Or More Ownership Interest
Organization
Ghc Holdings Llc
5% Or More Ownership Interest
Organization
Hccf Management Group Xi Llc
5% Or More Ownership Interest
Organization
Senior Care Genesis Llc
5% Or More Ownership Interest
Organization
Senior Care Holdings, Llc
5% Or More Ownership Interest
Organization
Sl Gen Llc
5% Or More Ownership Interest
Organization
Zac Properties Xi Llc
5% Or More Ownership Interest
Person
Stephen Young
Director/officer
Person
Arnold Whitman
Director/officer
Person
Arnold Whitman
5% Or More Ownership Interest
Person
Kenneth Silverwood
Director/officer
Person
Michael Sherman
Operational/managerial Control
Person
Michael Sherman
Director/officer
Person
Norman Schueftan
Director/officer
Person
Israel Rosenblum
Director/officer
Person
Robert Reitz
Operational/managerial Control
Person
Robert Reitz
Director/officer
Person
David Reis
Director/officer
Person
Joanne Reifsnyder
Director/officer
Person
Jeanne Phillips
Director/officer
Person
Garry Pezzano
Director/officer
Person
Isaac Neuberger
Director/officer
Person
Laurence Lane
Director/officer
Person
Wendy Labate
Operational/managerial Control
Person
Wendy Labate
Director/officer
Person
Robert Hartman
Director/officer
Person
Robert Hartman
5% Or More Ownership Interest
Person
George Hager
Operational/managerial Control
Person
George Hager
Director/officer
Person
Steven Fishman
Director/officer
Person
Steven Fishman
5% Or More Ownership Interest
Person
Christina Firth
Director/officer
Person
Jan Edwards
Director/officer
Person
Joseph Dvorak
Director/officer
Person
Thomas Divittorio
Operational/managerial Control
Person
Thomas Divittorio
Director/officer
Person
Keith Davis
Operational/managerial Control
Person
Keith Davis
Director/officer
Person
Gary Currier
W-2 Managing Employee
Person
Gary Currier
Operational/managerial Control
Person
Richard Castor
Director/officer
Person
Joseph Bourne
Director/officer
Person
Richard Blinn
Operational/managerial Control
Person
Richard Blinn
Director/officer
Person
David Bertha
Director/officer
Person
Michael Berg
Operational/managerial Control
Person
Michael Berg
Director/officer
Person
Brian Beckwith
Director/officer
Provider Resides in Hospital: No Number of Federally Certified Beds: 65 Number of Residents in Federally Certified Beds: 61 (94% occupied) Continuing Care Retirement Community: No Special Focus Facility: No With a Resident and Family Council: Both Automatic Sprinkler Systems in All Required Areas: Yes
Survey Date: Monday, November 19, 2012 Survey Type: Fire Safety Deficiency: K0018 (Corridor and hallway doors that block smoke.) Scope Severity Code: D Deficiency Corrected: Deficient, Provider Has Date Of Correction Date the deficiency was corrected: Friday, December 28, 2012 The inspection cycle of deficiency: 2 (the deficiency was found on a standard inspection)
Survey Date: Monday, November 19, 2012 Survey Type: Fire Safety Deficiency: K0029 (Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishi) Scope Severity Code: C Deficiency Corrected: Deficient, Provider Has Date Of Correction Date the deficiency was corrected: Friday, December 28, 2012 The inspection cycle of deficiency: 2 (the deficiency was found on a standard inspection)
Survey Date: Thursday, September 27, 2012 Survey Type: Health Deficiency: F0241 (Provide care for residents in a way that maintains or improves their dignity and respect in full rec) Scope Severity Code: D Deficiency Corrected: Deficient, Provider Has Date Of Correction Date the deficiency was corrected: Tuesday, October 30, 2012 The inspection cycle of deficiency: 2 (the deficiency was found on a standard inspection)
Survey Date: Friday, September 23, 2011 Survey Type: Fire Safety Deficiency: K0029 (Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishi) Scope Severity Code: B Deficiency Corrected: Deficient, Provider Has No Plan Of Correction The inspection cycle of deficiency: 3 (the deficiency was found on a standard inspection)
Survey Date: Friday, September 23, 2011 Survey Type: Fire Safety Deficiency: K0141 (No-smoking signs where oxygen is used.) Scope Severity Code: B Deficiency Corrected: Deficient, Provider Has No Plan Of Correction The inspection cycle of deficiency: 3 (the deficiency was found on a standard inspection)
Survey Date: Friday, September 23, 2011 Survey Type: Fire Safety Deficiency: K0145 (The appropriate emergency electrical system.) Scope Severity Code: C Deficiency Corrected: Deficient, Provider Has No Plan Of Correction The inspection cycle of deficiency: 3 (the deficiency was found on a standard inspection)
Survey Date: Thursday, September 22, 2011 Survey Type: Health Deficiency: F0315 (Ensure that each resident who enters the nursing home without a catheter is not given a catheter, un) Scope Severity Code: D Deficiency Corrected: Deficient, Provider Has Date Of Correction Date the deficiency was corrected: Monday, October 24, 2011 The inspection cycle of deficiency: 3 (the deficiency was found on a standard inspection)
Survey Date: Thursday, September 22, 2011 Survey Type: Health Deficiency: F0441 (Have a program that investigates, controls and keeps infection from spreading.) Scope Severity Code: D Deficiency Corrected: Deficient, Provider Has Date Of Correction Date the deficiency was corrected: Monday, October 24, 2011 The inspection cycle of deficiency: 3 (the deficiency was found on a standard inspection)
Survey Date: Thursday, September 22, 2011 Survey Type: Health Deficiency: F0280 (Allow residents the right to participate in the planning or revision of care and treatment.) Scope Severity Code: D Deficiency Corrected: Deficient, Provider Has Date Of Correction Date the deficiency was corrected: Monday, October 24, 2011 The inspection cycle of deficiency: 3 (the deficiency was found on a standard inspection)
Number of Facility Reported Incidents: 0 Number of Substantiated Complaints: 0 Number of Fines: 0 Number of Payment Denials: 0 Total Number of Penalties: 0 Total Amount of Fines in Dollars: USD 0
This data allows consumers to compare information about nursing homes. Information here is not an endorsement or advertisement for any nursing home and should be considered carefully. Use it with other information you gather about nursing homes facilities. Talk to your doctor or other health care provider about this.
This data was updated by using data source from Centers for Medicare and Medicaid Services (CMS) which is publicized on Wednesday, October 1, 2014. If you found out that something incorrect and want to change it, please follow this Update Data guide.
The Five Star Quality Rating System is not a substitute for visiting the nursing home. This system can give you important information, help you compare nursing homes by topics you consider most important, and help you think of questions to ask when you visit the nursing home. Use the Five-Star ratings together with other sources of information.
items
rating
Health Inspection Rating
(5 out of 5 stars)
Quality Rating
(5 out of 5 stars)
Staffing Rating
(4 out of 5 stars)
RN Staffing Rating
(5 out of 5 stars)
Overall Rating
(5 out of 5 stars)
Nursing homes vary in the quality of care and services they provide to their residents. Reviewing health inspection results, staffing data, and quality measure data are three important ways to measure nursing home quality. This information gives you a "snap shot" of the care individual nursing home give.
Patients experiences
Provider
State
Nation
Percent of High Risk Long Stay Residents With Pressure Ulcers
N/A
4%
6%
Percent of Long Stay Residents Experiencing One or More Falls with Major Injury
N/A
4%
3%
Percent of Long Stay Residents Who Self Report Moderate to Severe Pain
N/A
10%
8%
Percent of Long Stay Residents Who Were Physically Restrained
N/A
N/A
1%
Percent of Long Stay Residents Whose Need for Help with ADLs has Increased
N/A
14%
16%
Percent of Long Stay Residents with a Catheter Inserted and Left in Their Bladder
N/A
4%
3%
Percent of Long Stay Residents With a Urinary Tract Infection
N/A
6%
6%
Percent of Short Stay Residents Who Self Report Moderate to Severe Pain
N/A
23%
19%
Percent of Short Stay Residents With Pressure Ulcers That Are New or Worsened
N/A
1%
1%
Percent of Long Stay Residents Assessed and Appropriately Given the Pneumococcal Vaccine
N/A
95%
94%
Percent of Long Stay Residents Assessed and Appropriately Given the Seasonal Influenza Vaccine
N/A
97%
94%
Percent of Long Stay Residents Who Have Depressive Symptoms
N/A
10%
6%
Percent of Long Stay Residents Who Lose Too Much Weight
N/A
8%
7%
Percent of Long Stay Residents Who Received an Antipsychotic Medication
N/A
19%
20%
Percent of Low Risk Long Stay Residents Who Lose Control of Their Bowel or Bladder
N/A
62%
44%
Percent of Short Stay Residents Assessed and Appropriately Given the Pneumococcal Vaccine
N/A
86%
83%
Percent of Short Stay Residents Who Newly Received an Antipsychotic Medication
N/A
2%
2%
Percent of Short Stay Residents Who Were Assessed and Appropriately Given the Seasonal Influenza Vaccine
N/A
86%
84%
N/A
Data not available.
See more related providers
Reviews
Sedgewood Commons [Federal No:205159] near 22 Northbrook Dr, Falmouth ME